2KW series intelligent battery chargers
2KW BSC series intelligent battery chargers
Main technical parameters of product
|
Brand |
Xingzhongke |
|
Input voltage |
Single-phase AC220V±15% or AC110V±15%;50/60HZ |
|
Rated charging voltage |
DC 12V,24V,36V,48V,60V,72V,80V,96V,108V,120V,240V(Other parameters can be customized) |
|
Charging current |
DC 3A,5A,10A,15A,20A,30A,40A,50A,60A(Other parameters can be customized). |
|
Suitable battery types |
Lithium battery,Lead-acid batteries, nickel-cadmium batteries, nickel-metal hydride batteries, and more than 90% of the battery types on the market |
|
Output accuracy |
CV≤0.5%,CC≤1% |
|
Efficiency |
≥90%,under full load conditions |
|
Display |
A 46*33mm high-definition LCD shows the charging voltage, charging current, battery power, charging status. Both the charging voltage and current are displayed in 4-digit numbers |
|
Charging curve |
Different types of batteries correspond to dedicated charging curves, and the charging curves can also be customized (indicate the battery type when placing an order) |
|
Charging process |
Power on - Check battery voltage - Automatically turn on the output - Charge according to the charging curve - Automatically turn off after full charge or maintain a long-term online floating charge mode |
|
Cooling method |
Intelligent temperature-controlled fan for heat dissipation. The fan starts to rotate when the internal temperature of the machine is higher than 40°C |
|
Protection |
Output over-voltage, overload, short circuit, battery reverse connection, and overall machine over-temperature protection. The over-temperature protection threshold is (80 - 85) °C |
|
Fault indication method |
When a fault occurs in the charger, it will automatically shut down and indicate the fault |
|
Setting method |
Set with a digital encoder. The set values are memorized even after power off |
|
Communication interface |
RS485、CAN can be optionally configured |
|
Insulation strength |
Input - output: AC1500V, 10mA, 1 minute Input - chassis: AC1500V, 10mA, 1 minute Output - chassis: AC1500V, 10mA, 1 minute |
|
Operating environment requirements |
Indoor, altitude ≤ 2000m, relative humidity: ≤ 80% (non - condensing), ambient temperature (-15 - 45)℃, pollution degree: 2 |
|
Storage environment requirements |
Indoor, relative humidity: ≤ 80%, ambient temperature: (-20 - 70)℃
|
|
Dimensions |
L260*W140*H100mm |
|
Weight |
4kg |
Selection reference for the 2KW BSC series. Parameters not listed can be customized.
Note: The suffix LA stands for lead-acid, and LI stands for lithium battery.
|
Model |
Charging voltage |
Charging current |
Rated power |
|
BSC-12V50A-2LA\LI |
10-15V |
0-50A |
750W |
|
BSC-12V60A-2LA\LI |
10-15V |
0-60A |
900W |
|
BSC-24V20A-2LA\LI |
20-30V |
0-20A |
600W |
|
BSC-24V30A-2LA\LI |
20-30V |
0-30A |
900W |
|
BSC-24V40A-2LA\LI |
20-30V |
0-40A |
1200W |
|
BSC-24V50A-2LA\LI |
20-30V |
0-50A |
1500W |
|
BSC-24V60A-2LA\LI |
20-30V |
0-60A |
1800W |
|
BSC-36V20A-2LA\LI |
30-45V |
0-20A |
900W |
|
BSC-36V30A-2LA\LI |
30-45V |
0-30A |
1350W |
|
BSC-36V40A-2LA\LI |
30-45V |
0-40A |
1800W |
|
BSC-48V15A-2LA\LI |
40-60V |
0-15A |
900W |
|
BSC-48V20A-2LA\LI |
40-60V |
0-20A |
1200W |
|
BSC-48V30A-2LA\LI |
40-60V |
0-30A |
1800W |
|
BSC-60V10A-2LA\LI |
55-75V |
0-10A |
750W |
|
BSC-60V15A-2LA\LI |
55-75V |
0-15A |
1125W |
|
BSC-60V20A-2LA\LI |
55-75V |
0-20A |
1500W |
|
BSC-60V25A-2LA\LI |
55-75V |
0-25A |
1875W |
|
BSC-72V10A-2LA\LI |
70-90V |
0-10A |
900W |
|
BSC-72V15A-2LA\LI |
70-90V |
0-15A |
1350W |
|
BSC-72V20A-2LA\LI |
70-90V |
0-20A |
1800W |
|
BSC-96V10A-2LA\LI |
90-120V |
0-10A |
1200W |
|
BSC-96V15A-2LA\LI |
90-120V |
0-15A |
1800W |
|
BSC-108V5A-2LA\LI |
100-135V |
0-5A |
675W |
|
BSC-108V10A-2LA\LI |
100-135V |
0-10A |
1350W |
|
BSC-108V15A-2LA\LI |
100-135V |
0-15A |
2025W |
|
BSC-120V5A-2LA\LI |
120-150V |
0-5A |
750W |
|
BSC-120V10A-2LA\LI |
120-150V |
0-10A |
1500W |
|
BSC-240V3A-2LA\LI |
240-300V |
0-3A |
900W |
|
BSC-240V5A-2LA\LI |
240-300V |
0-5A |
1500W |